The TL1-A intrinsically safe thermometer is intended to be used anywhere a precision glass stem thermometer or other type thermometer may be used. |
The TL1-A is an improved version of the original ThermoProbe model TL1. The TL1-A incorporates glass thermometer simplicity and reliability with the ease of a digital display. Like precision mercury thermometers, the TL1-A has accuracy, repeatability and long-term stability. But unlike those thermometers there will never be problems with mercury separation or hazardous material cleanup. Different from most electronic thermometers, the "Cordless" TL1-A has no wires to get in the way or break. Battery replacement is easily done through a sealed cover. Encoded calibration is unaffected by temperature, vibration, or battery removal. Low battery display, and failure mode indications protect the user from false data. |
4 Point NIST Traceable Calibration and a one year warranty included. |
US EPA Phase-Out of Mercury Thermometers Used in Industrial and Laboratory Settings |
NIST GMP 11 - Good Measurement Practice for Assignment and Adjustment of Calibration Intervals for Laboratory Standards |
|
KEY FEATURES |
- Auto-off after 20 minutes to save battery life
- Minimum reading
- Maximum reading
- Averaging
- Easy °F to °C switching
- Display arrows indicate increasing or decreasing temperature activity
|
|
|
Display: |
LCD with 0.25 inch characters
Trend Indicating Arrows
Low Battery & Fault indication |
User Functions: |
Auto Off after 20 minutes or continuous operation
Lowest Reading, Highest Reading, Average Reading
Switchable in Units of °F or °C
Display tenths or hundredths resolution |
Construction: |
Stainless Steel temperature sensor; Standard Sensor length 8" (20cm)
Standard diameter 1/4" (6.35mm) with reduced diameter tip of 3/16" (4.76mm)
Sensor mount acetyl plastic
Electronics and display in 3.5" x 1.2" anodized Aluminum enclosure
Molded Silicone seal.
Highly durable display window, graphics and membrane switches.
|
Weight: |
3 ounces, 93 grams |
Temperature: |
Resolution 0.01 Degrees
Calibrated Accuracy:
±0.1°F from 14 to 320°F
±0.06°C from -10 to 160°C
NIST Traceable Report of Test |
Temperature Time Constant: |
8 seconds in circulated water bath
(63.2% response to temperature change) |
Electronics: |
Microcontroller and precision 20 bit A/D Converter
FLASH memory
Recommended Temperature Range For best Accuracy 32 to 112°F, 0 to 44°C
100 Ohm, Class A Platinum RTD
Immersion depth 4", 11cm |
Sensor: |
100 Ohm, Class A 1/3 DIN RTD
Immersion depth 4", 11cm |
Battery: |
20mm Coin Size 3V Lithium, Duracell Type CR2032
Over 100 hours Service Life at 70°F, 21°C
Battery Operating Range -4 to 130°F, -20 to 54°C
Note: Battery may not provide adequate power if ambient temperature is below -4°F, -20°C or above 130°F, 54°C |
|
|
Distillations, temperature baths, melting point tests, flash point tests, reference, thermowells, provers, temperature calibration for flow meters. |
Industries: |
Laboratory
Petroleum
Pipeline
Pharmaceutical
Food |
|
|
|
|
|
|